PIR Motion Sensor: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
|||
| Line 14: | Line 14: | ||
RL2: This variable resistor allows us to set the detection range, which could vary betwen 3-7m.'' |
RL2: This variable resistor allows us to set the detection range, which could vary betwen 3-7m.'' |
||
<pre> |
|||
Dimension: 3.2cm x 2.4cm x 1.8cm (approx) |
|||
Infrared sensor with control circuit board |
|||
The sensitivity and holding time can be adjusted |
|||
Working Voltage Range: DC 4.5V- 20V |
|||
Current drain:<60uA |
|||
Voltage Output: High/Low level signal:3.3V TTL output |
|||
Detection distance: 3--7M(can be adjusted) |
|||
Detection range: <140° |
|||
Delay time: 5-200S(can be adjusted, default 5s +-3%) |
|||
Blockade time: 2.5 S (default) |
|||
Trigger: L: Non-repeatable trigger H: Repeat Trigger (default) |
|||
Work temperature:-20-+80°C |
|||
Trigger Method: L unrepeatable trigger / H repeatable trigger |
|||
</pre> |
|||
Revision as of 20:44, 4 April 2013
Application à la détection de mouvement : camera de surveillance, économie d'énergie, ...
SEN-08630
SKU 139624 (HC-SR501)
- http://dx.com/p/ir-infrared-motion-detection-sensor-module-dc-5v-20v-139624
- http://blog.roman-mueller.ch/index.php/2013/01/26/hc-sr501-passive-infrared-sensor-with-arduino/
- http://zygzax.com/2012/11/17/sensor-de-movimiento-pir-hc-sr501/?lang=en
The HC-SR501 Module has three connection pins: +5v, OUT(3.3v) and GND; and two variable resistors for calibration (Ch1 and RL2).
Ch1: With this resistor, we can set the time that the output of the sensor will be active. One of the main limitations of this module is that the minimum time is about 3s. If we change the variable resistor to another of 100K, we can decrease the minimum time to approximately 0.5 s.
RL2: This variable resistor allows us to set the detection range, which could vary betwen 3-7m.
Dimension: 3.2cm x 2.4cm x 1.8cm (approx)
Infrared sensor with control circuit board
The sensitivity and holding time can be adjusted
Working Voltage Range: DC 4.5V- 20V
Current drain:<60uA
Voltage Output: High/Low level signal:3.3V TTL output
Detection distance: 3--7M(can be adjusted)
Detection range: <140°
Delay time: 5-200S(can be adjusted, default 5s +-3%)
Blockade time: 2.5 S (default)
Trigger: L: Non-repeatable trigger H: Repeat Trigger (default)
Work temperature:-20-+80°C
Trigger Method: L unrepeatable trigger / H repeatable trigger